Description
THIS ITEM IS NON-RETURNABLE. NO WARRANTY IF IT’S NOT INSTALLED BY THE MFG (SECURE CARE) CERTIFIED INSTALLER
DISCLAIMER: Secure Care Products are not available to customers outside
the state of North Carolina.
Description:
The EXIU Communication Hub is designed to provide a method of message
control for all field installed devices using the CAN bus architecture for su-
pervision and event message transmission. Up to 95 total devices may be
connected to one EXIU unit. Each device will require its own uniquely pro-
grammed addressable ID. The EXIU passes the input messages through to a
PC based Secure Care Software graphical annunciator.
The EXIU has two form C output relays (dry contacts) that will activate
(change state) during cutband alarms. These two relays can be used to trigger
a remote annunciator or any other device which may be triggered by a dry
contact.
The EXIU Panel is subject to Secure Care’s “Standard Terms and Conditions
of Sale” and “General Product Warranty Statement”. The provisions may be
viewed by following the “Legal Links” at www.securecare.com
Features:
Non-Volatile Memory
* Two Form C Dry Contacts
*Battery Back-up
*Communication Hub for devices on CAN Bus
*Supervision of CAN bus
* Easy Installation, Water Resistant
Meets the requirements of FCC Part 15, Subpart B
* Meets the requirements of IC, ICES-003
*Bypass unlock door during cutband alarm
*On board self tests. Test CAN & number of device connected to EXIU
*Clear Memory-Wipe Node
* Lock down, Set all doors to lock
*Code to set featured can be customer selectable—3 digit cod
Interface Capability:
Secure Care Software 2.X Version
CCTV-Closed Cir cuit Television, Paging Systems (dr y contact)
CAN-Contr oller Ar ea Networ k
Any other device which may be triggered by a dry contact
Pre-packaged Kits:
EXIU Panel: A01350925
EXIU Surface Mount Kit: 845
EXIU Flush Mount Kit: 844
Electrical Specifications:
Input Power: 12V DC, 1 Amp Plug in Wall Adapt-er or Secure Care approved 12VDC. Central PS w/Battery Backup on emergency power circuit
Battery Back-up: 3 AAA Batteries
Battery Back up Time: 30 minutes (standby mode)
AUX Relay (2): 30 V DC, 1 amp max.
Current Draw: 125 mA
Construction Specifications:
Front Panel: ABS
Keypad with Graphics: Polyester
Mounting: Surface or Flush Mount
Terminal Connections: Pluggable Terminal Block, Top Wire Entry
Exit Panel Compo-nents: Surface Mounted Components, PCB Assembly
Additional Equipment Required: Mounting Boxes for EXIU Panel
Surface Mount Box Kit: 460
Flush Mount Box Kit: 461
2 Hour Fire Rated Flush Mount Box Kit: 462